Preparing Buffers

Online buffer composition correction system

Functional configuration for online mixing and control of buffer parameters.

Product Description

The solution preparation system performs calculation, dosing and regulation of the composition in automatic mode. Concentrated one-component solutions are supplied to the input, and a mixture with a given molar concentration, pH and electrical conductivity is formed at the output.

Multi-stage dynamic control and feedback allow you to continuously obtain the required solution. The number of threads and configuration are customized to suit the customer's task.

Models and versions

Models and versions: Online buffer composition correction system
ModelConsumption, l/minPipelinePower, kWWeight, kg
AIC030Q0.05-3DN101.5525
AIC100Q0.3-10DN152680
AIC200Q0.5-20DN204700
AIC400Q2.5-40DN255900
AIC800Q2.5-80DN4010.51200
AIC1600Q10-160DN50121600

Product Features

Online mixing

Three, four or more input streams are combined according to a given recipe.

Automatic calculation

The computer calculates and adjusts the composition instead of manual adjustment.

Feedback

pH and conductivity are monitored in real time.

PID regulation

Dynamic control maintains the required mixture parameters.

Valve control

The system monitors the opening status of the valves.

Data recording

Computer control ensures process traceability.

Technical Parameters

Technical parameters: Online buffer composition correction system
ParameterMeaning
Cooking channels3-6
Stabilization time<2 min
Dilution factor3-100
System measurement/flow accuracy±0.5% / ±2%
pH sensor0-14; resolution 0.01; accuracy ±0.05
Maximum working pressure5 bar
Contact materials316L, PP, EPDM
Operating temperature2-40 °C
Degree of protectionIP54

Frequently asked questions

What solutions are supplied to the inlet?

Concentrated one-component solutions from which a mixture with specified characteristics is formed.

What parameters are adjustable?

Molar concentration, pH and electrical conductivity of the output solution.

How many channels are available?

The standard table shows 3-6 channels; the configuration is determined by the technological task.