UF/DF and filtration
Ultrafiltration production system
Automatic TFF system for clarification, concentration, diafiltration and buffer change.
Product Description
Fully automated tangential ultrafiltration system for biopharmaceutical production. Used for clarification of cell fluids, concentration of biomolecules, diafiltration and membrane separation.
The modular design allows you to select the design according to the technological task. The sanitary fluid path, standard membrane cassette holders and touch panel are combined with a common control system.
Models and versions
| Model | Consumption, l/min | Membrane area, m² | Pipeline | Power, kW | Weight, kg |
|---|---|---|---|---|---|
| AF0050 | 5-50 | 1-5 | DN25 | 3 | 700 |
| AF0100 | 10-100 | 2.5-10 | DN40 | 6 | 950 |
| AF0200 | 20-200 | 5-20 | DN50 | 6 | 1500 |
| AF0300 | 30-300 | 5-40 | DN65 | 9 | 1700 |
| AF0400 | 40-400 | 10-80 | DN80 | 9 | 1800 |
| AF0800 | 80-800 | 20-120 | DN100 | 9 | 2200 |
| AF1600D | 100-1000 | 100-200 | DN100 | 17 | 2500 |
Product Features
Modular design
The equipment is adapted to the performance and membrane area.
Membrane cassettes
Standard holders are compatible with cassettes from well-known manufacturers.
Compact path
Multi-level pipelines reduce residual volume.
Touch interface
Graphic display and full touch control.
Traceability
The computer system supports the recording of process data.
Remote control
Remote monitoring of the operating condition of equipment.
Technical Parameters
| Parameter | Meaning |
|---|---|
| Maximum working pressure | 5 bar |
| Pressure sensor | -1...9 bar; accuracy ≤0.3% |
| pH | 0-14 |
| Electrical conductivity | 1 µS/cm - 300 mS/cm |
| Modes | Constant TMP, pressure, flow and speed; recharge by mass; water flow test |
| Contact materials | 316L, PP, EPDM, borosilicate glass, PEEK |
| Operating temperature | 2-40 °C |
| Degree of protection | IP54 |
| Food | 380 V AC (±10%), 50/60 Hz, 3P+N+PE |
Frequently asked questions
What operations is the system used for?
For clarification, concentration, diafiltration and membrane separation of biological products.
How much membrane area is supported?
The range depends on the model: from 1-5 m² for AF0050 to 100-200 m² for AF1600D.
Is there automatic refill?
Yes. The control modes provide automatic replenishment based on mass.