High Pressure Chromatography HPLC

Preparative chromatography system

High-pressure system for feeding, elution and collection of fractions in preparative purification.

Product Description

The preparative chromatography system combines a pump, detector and workstation. Performs sample and mobile phase injection, flow control, elution and fraction collection.

Available with diaphragm pump and proportional valve or with double plunger pump. Software control and layout adapt to the production process.

Models and versions

Models and versions: Preparative chromatography system
ModelConsumption, l/hLoginExitMax. pressure, barAccuracyDimensions, L × W × H, mm
HAP090G-EX9-906 mm1/8"100±1%1500 × 1300 × 2000
HAP200G-EX20-20010 mm6 mm100±1%1700 × 1300 × 2000
HAP300G-EX30-3001/2"3/8"100±1%1700 × 1300 × 2000
HAP500G-EX50-5001/2"3/8"100±1%2400 × 1300 × 2000
HAP1000G-EX100-10003/4"1/2"100±1%2600 × 1500 × 2000
HAP1600G-EX160-16001"0.5"100±1%2600 × 1500 × 2000
HAP2500G-EX250-25001.5"3/4"100±1%2800 × 1500 × 2000
HAP3200G-EX320-32001.5"1"70±1%2800 × 1500 × 2000
HAP060D-EX6-606 mm1/8"100±1%1000 × 1100 × 2000
HAP180D-EX18-18010 mm6 mm100±1%1700 × 1200 × 2000
HAP300D-EX30-3001/2"3/8"100±1%2150 × 1200 × 2000
HAP600D-EX60-6001/2"3/8"100±1%2150 × 1200 × 2000
HAP1200D-EX120-12003/4"1/2"100±1%2400 × 1500 × 2000
HAP1800D-EX180-18001"0.5"100±1%2400 × 1500 × 2000
HAP2400D-EX240-24001.5"3/4"100±1%2400 × 1500 × 2000

Product Features

Two pumping schemes

Diaphragm pump with proportional valve or double plunger pump.

Elution control

The workstation combines sample supply, mobile phase and fraction collection.

Reproducibility

Controlled feed maintains process repeatability.

Explosion-proof version

The system has an ExdII BT4 design.

Technical Parameters

Technical Parameters: Preparative Chromatography System
ParameterMeaning
Series GDiaphragm pump and proportional valve
Series DDouble plunger pump
Overall flow accuracy±1%
Main nodesPump, detector, workstation
FunctionsSample and mobile phase supply, elution, fraction collection
Explosion-proof designExdIIBT4

Frequently asked questions

What is the difference between the G and D series?

The G series uses a proportional valve diaphragm pump, the D series uses a double plunger pump.

What operations does the system perform?

Flow control, sample and mobile phase supply, elution and fraction collection.

Are the pressures the same for all models?

No. The HAP3200G-EX has a maximum pressure of 70 bar; for the other listed versions, 100 bar is indicated.